SLAB THICKNESS 17 CM

DOSAGE FIBRATEC V12-AM: 2 kg / m³

The máximum permisible static point load is 4275 kg

The Dynamic load for:

50 repetitions/day: 4085 kg

100 repetitions/day: 3800 kg

200 repetitions/day: 3373 kg

300 repetitions/day: 3135 kg

The recommended distances between the shrinkage joints are:

Indoor slab: 4m - 5m

Outdoor slab: 3,5m - 4m

Depth of cut joint: 5,5 cm

DOSAGE FIBRATEC V12-AM: 3 kg / m³

The máximum permisible static point load is 4500 kg

The Dynamic load for:

50 repetitions/day: 4300 kg

100 repetitions/day: 4000 kg

200 repetitions/day: 3550 kg

300 repetitions/day: 3300 kg

The recommended distances between the shrinkage joints are:

Indoor slab: 4m - 5m

Outdoor slab: 3,5m - 4m

Depth of cut joint: 5,5 cm